BFVYY - LAMINAR X-500 HRDNER(50-C-3)(2ND REFORMLTN)

  • MSDS: BFVYY
  • Manufacturer: MIDLAND DIV THE DEXTER CORP
  • Product Name: LAMINAR X-500 HRDNER(50-C-3)(2ND REFORMLTN)
  • National Stock Number: 8030-00-908-0362
Product Identification

Product ID:LAMINAR X-500 HRDNER(50-C-3)(2ND REFORMLTN)
MSDS Date:01/01/1987
FSC:8030
NIIN:00-908-0362
Kit Part:Y
MSDS Number: BFVYY

Responsible Party
MIDLAND DIVISION,THE DEXTER CORPORATION
31500 HAYMAN ST
HAYWARD, CA 94544-7120
US

Cage: 98795

Contractor
DEXTER CORP THE DEXTER CROWN METRO AEROSPACE DIV
HAYWARD, CA 94544-7120 US

Telephone: 510-471-7171

Cage: 98795

Ingredients

TOLUENE-2,4-DIISOCYANATE (TDI) (SARA III)

CAS: 584-84-9

RTECS: CZ6300000

Fraction By Weight: 0.6%

OSHA PEL C,0.02 PPM/0.02 STEL

ACGIH TLV: 0.005PPM/0.02STEL;93

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


1 METHOXY 2 PROPANOL ACETATE (CAS # 108-65-6)

Fraction By Weight: 25%


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 15%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Effects of Overexposure:INH:ANESTH;IRRIT RESP TRACT,ACUTE CNS DEPRESS
W/HDCH,DIZ,STAG GAIT,CONFUS,UCON,COMA. SKIN/EYE:IRRIT

First Aid

First Aid:FUMES: REMOVE FROM EXPOS. RESTORE BREATHING. KEEP WARM &
QUIET. NOTIFY MD. EYES:FLUSH IMMED W/COPIOUS QTY OF RUNNING WATER
AT LEAST 15 MIN. SEE MD FOR DEFINITIVE TREATMENT. SKIN:REMOVE
W/SOAP & WATER. REMOVE CONTAMINATED CLOTHING.

Fire Fighting

Flash Point:92F SCC
Lower Limits:0.9
Extinguishing Media:CO*2,DRY CHEMICAL,FOAM FOR CLASS IB FLAM LIQ
Fire Fighting Procedures:USE WATER FOG TO COOL CLSD CONTAINERS EXPOS TO
FIRE.
Unusual Fire/Explosion Hazard:KEEP CANS TIGHTLY CLSD. KEEP FROM IGNIT
SOURCES. CLSD CANS MAY EXPLO FROM HEAT EXPOS. SEE OTHER PREC

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION(FLAMES,HOT
SURFACES, & ELECTRICAL,STATIC OR FRICTIONAL SPARKS). AVOID
BREATHING VAPORS. VENTILATE AREA. REMOVE W/INERT ABSORBENT &
NON-SPARKING TOOLS.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LG QTY
IN BUILDINGS DESIGN FOR STORAGE OF NFPA CLASS II FLAM LIQ. DO NOT
TAKE INTERNALLY. GROUND CONTAINER WHEN POURING
Other Precautions:AVOID FREE FALL OF LIQ IN EXCESS OF A FEW INCHES. DO
NOT FLAME CUT,BRAZE,OR WELD W/O NIOSH APROVED RESP OR APPROP
VENTILATION. UNUSUAL FIRE/EXPLO HAZ: DO NOT APPLY TO HOT SURFACES.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVD RESP PROT REQD. VARIES
W/CONDITIONS OF USE.
Ventilation:GEN DILTN/LOC EXHST IN VOLUME & PATTERN TO KEEP Protective Gloves:PRLNG/RPTD EXPO
Eye Protection:SAFETY EYEWEAR FOR SPLASH
Other Protective Equipment:PREVENT PROLONGED SKIN CONTACT
W/CONTAMINATED CLOTHING
Supplemental Safety and Health
DATE OF PREP: 4-10-85.

Chemical Properties

Boiling Pt:B.P. Text:281-331F
Vapor Pres:9.5
Vapor Density:>1.0
Spec Gravity:1.1057
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:48

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:SOURCES OF IGNITION
Hazardous Decomposition Products:FUMES FROM HEATING TO DECOMP:CO,OXIDES
OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOS OF IAW LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.